Cadd pump manual






















CADDManualFDM. CADD Manual - FDOTSS10, FDOTC3D This CADD Manual is to be used by all in-house personnel producing engineering projects. It is to be included in all contracts requiring engineering plans preparation. This manual will affect all offices of the Department and all consultants, contractors and others who utilize. This manual is designed for clinicians and contains all of the information needed to fully program the pump. Do not give this manual to patients as it would allow them complete access to all programming information. The CADD-MS ™ 3 Ambulatory Infusion Pump is designed for subcutaneous, intravenous, epidural and intrathecal infusion of medication. CADD®-Solis is the only pump to combine PIB and PCA. The intuitive task based software and therapy-based drug protocol library is familiar to users, promoting usability and safety. Scalable platform - Designed to satisfy hospital’s current and future clinical requirements and health information technology initiatives.


ii PROOF (LR #), D. Zurn «F §0 PCA-R (X9)» This manual pertains only to the Deltec CADD-PCA®, Model R, infusion pump. The issue date of this Operator 's Manual is included for the clinician 's information. In the event one year has elapsed between the issue date and product use, the. the bag/container and the CADD pump. Once the CADD pump is programmed the lines are ASEPTICALLY attached to the CADD pump. A new cassette for the CADD pump may be delivered in a number of ways. RNSH will deliver the Cassette with an extension set and one Flat Epidural Filter attached. This Cassette has a life of 5 days. Cadd Solis Technical Manual. An icon used to represent a menu that can be toggled by interacting with this icon.


Description of the CADD®-Solis VIP Pump The CADD®-Solis VIP ambulatory infusion pump provides measured drug therapy to patients in hospital or outpatient settings. Therapy should always be overseen by a physician or a certified, licensed healthcare professional. As appropriate, the caregiver and patient should be instructed in using the pump. This manual is designed for clinicians and contains all of the information needed to fully program the pump. Do not give this manual to patients as it would allow them complete access to all programming information. The CADD-MS ™ 3 Ambulatory Infusion Pump is designed for subcutaneous, intravenous, epidural and intrathecal infusion of medication. 1. Press T. Pump displays Stop pump? 2. Press Yes. Pump displays Pump is stopping. 3. Clamp the tubing and disconnect from the patient. 4. Unlock the cassette latch and remove the empty cassette. 5. Attach a new cassette (see Attaching cassette / administration set). 6. Set Reservoir Volume? press Yes. 7. Enter security code (see Unlocking the pump). 8.

0コメント

  • 1000 / 1000